Gas Select Composer™ Gas Mix Calibration 

Use Composer™ to create and store 20 custom gas mixtures with up to 5 constituent gases from the 98-130 Gas Select™ gas list on Alicat laminar DP mass flow meters and controllers.

Measure custom gas mixes without any change in accuracy, thanks to laminar DP technology and Alicat’s extensive library of gas properties.

  • 20 custom gas mixes: Create 20 Composure™ gas mixes simultaneously on each device, each stored in the on-board gas list with your factory gas calibrations.
  • Up to 5 gases per mixture: Define gas compositions to 0.01% for each of up to 5 constituent gases from the 98-130 preloaded gas calibrations.
  • NIST-traceable accuracy: Composer™ software calculates the viscosity of the custom gas mixture and loads the NIST-traceable gas properties of the new mix into the flow measurement calculation, without compromising measurement accuracy.
  • Easy to use: Use the menu interface to create your gas compositions, or generate gas lists for multiple units in seconds with single-line RS-232 serial commands. Users may switch between selected gases and gas mixtures without any need for instrument recalibration
Gas Select Screen

Gas Select preloaded gas calibrations

Gas select screen

Gas Select menu

gas select screen

Composer™ mixes

FastTrack Ordering

Hydrogen mass flow instruments that ship in just 3-5 business days.
CALIBRATION
Standard or High Accuracy
DISPLAY
Monochrome, Color, or None
PROTOCOL
Analog, RS-232, RS-485, or Modbus RTU
CONNECTOR
MD8, Locking Industrial, DB9M, DB15
FITTINGS
NPT

METER RANGES

2 SCCM – 500SLPM

CONTROLLER RANGES

2 SCCM – 100SLPM

Service and Support

Whether it is time for your instrument’s annual recalibration or your instrument needs a repair or upgrade,
you can fill out the Service Request Form below, email us, call us, or start a live chat session to get the service process started.

7641 N Business Park Dr. Tucson, AZ 85743

service@alicat.com

+1(888)290-6060

FastTrack Ordering

M/MC mass flow meters and controllers that ship in just 3-5 business days.
CALIBRATION
Standard or High Accuracy
DISPLAY
Monochrome, Color, or None
PROTOCOL
Analog, RS-232, RS-485, or Modbus RTU
CONNECTOR
MD8, Locking Industrial, DB9M, DB15
FITTINGS
NPT

METER RANGES

2 SCCM - 500SLPM

CONTROLLER RANGES

2 SCCM - 100SLPM

Service and Support

Whether it is time for your instrument’s annual recalibration or your instrument needs a repair or upgrade,
you can fill out the Service Request Form below, email us, call us, or start a live chat session to get the service process started.

7641 N Business Park Dr. Tucson, AZ 85743

Geograaf 24
6921 EW
Duiven, The Netherlands