Alicat Part Number Decoder
There are many ways to customize your Alicat, but added options can sometimes make your part number look like alphabet soup. We’ve compiled the listings below to help you decipher the various elements of your Alicat part number.
Most Alicat part numbers consist of a top-level part number and a group of adder codes. Top-level part number elements are separated by hyphens (-), and adder codes are separated by commas (,). A forward slash (/) separates these two groups of your Alicat part number.
Top level part numbers
MCRWD-40SLPM-TFTRD-DB15-MODBUS-485-54X54-SAE-EPDM-CC / CM, 102P, RIN, CIN, GAS: CH4, RANGE (85 SCFH), CLV, PU: V, TOT (99999.99 SCF), BAUD: 38400, STP: 20°C, CPNT (5, 10%), 17025, DS
Mainline Laminar DP Mass Flow and Pressure Devices
Adder Codes
MCRWD-40SLPM-TFTRD-DB15-MODBUS-485-54X54-SAE-EPDM-CC / CM, 102P, RIN, CIN, GAS: CH4, RANGE (85 SCFH), CLV, PU: V, TOT (99999.99 SCF), BAUD: 38400, STP: 20°C, CPNT (5, 10%), 17025, DS
Analog Type
1x 1-5 Vdc
5x 0-5 Vdc
10x 0-10 Vdc
Cx 4-20 mA
x2x Secondary signal
Analog Inputs
xIN Setpoint input
Analog Outputs
xM Gas mass flow output
xP Pressure output
xT Temperature output
xV Gas or liquid volumetric flow output
- 17025 ISO17025 certification (sometimes written as 17025HF or 17025LF)
- AGB Absolute, guage, and baro pressure in data frame
- ALHx: y High flow alarm above y setpoint
- ALLx: y Low flow alarm below y setpoint
- 5 5 Vdc analog output
- 12 12 Vdc analog output
- 24 24 Vdc analog output
- OD 500 mA open drain
- AVG OFF Averaging off
- BAUD: x Baud rate
- BD Bidirectional flow or gauge pressure calibration
- CLP Closed-loop pressure control
- CLPG Closed-loop gauge pressure control
- CLR Closed-loop ramp
- CLV Closed-loop volumetric flow control
- CPNT (x,y%) Additional calibration points
- DB: x Deadband x% preset
- DS Downstream valve placement
- FLOW Flow rate for tuning pressure control, e.g. FLOW (10 SLPM, H2)
- GAS: x Initial gas selection
- HC High-accuracy flow or pressure calibration
- HLCV Helium leak check under vacuum
- HLCP Helium leak check under positive pressure
- ID: x RS-232/485 unit address
- [IPx] Custom secondary output on industrial connector
- LCK Display locked
- LIQUID: x Custom liquid calibration, not required for water
- LVD Valve drive % shown on display
- MAXAVG Maximum geometric running averaging
- NONWAR Any damage caused will not be covered under warranty
- NO-SERVICE No returns or repairs
- NTP: x Custom NTP conditions
- OPL: x Overpressure limit for valve closure
- OXC Oxygen cleaning
- P1: x Expected inlet pressure, e.g. P1:100 PSIG, P2: 50 PSIG
- P2: x Expected outlet pressure
- PD (x, y) Custom P=x and D=y valve tuning
- PD2I (x, y, z) Custom P=x, D=y, and I=z valve tuning
- POP Power over Profibus
- PROFIBUS: x Profibus unit address
- PRANGEX Pressure ranges of internal and external sensors
- PU: x Selects flow parameter on power-up
- PUB Power up with backlight on
- PUGS: x Gas selection on power-up
- PUL: x Pulsed analog output at x flow total
- PUSP: x Setpoint on power-up
- PUT: x Tare after x seconds on power-up
- RANGE (x) Custom calibration range
- RCPNT (x,y,z) Replacement calibration points
- RD: x Length of cable for remote display
- RIN Local selection of analog/digital setpoint
- RTL Right-to-left flow direction
- RVD Valve drive % shown in serial data
- SENIN: x External pressure sensor input signal
- SR: x Streaming rate in x milliseconds
- STP: x Custom STP conditions
- STR Preset to streaming mode
- TOT Integrated flow totalizer
- TOT (x y, R/F/E) Custom resolution x and/or units y
- E Rolls over and flashes OVR error at max count
- F Freezes and flashes OVR error at max count
- R Rolls over at max count
- TOTAVG Totalizer averaging
- TOTBDx Bidirectional totalizers:
- TOTBD1 Negative values subtract from total
- TOTBD3 Negative values have no effect
- TOTBD4 Negative values ignored, resets at zero
- TOTR Reset totalizer on selected pin
- VOL: x Expected closed volume x