ISMC Series Flow Controller
For gas flow control in continuously explosive gas atmospheres
Integrated Valve
- 98 gas calibrations pre-loaded
- 0.5 SCCM – 250 SLPM
- 11.5 – 160 PSIA (high pressure option to 320 PSIA)
- Accuracy of flow as good as ± 0.5% of reading or ± 0.1% of full scale, whichever is greater
- See certificates below
Spec Sheets
ISMCS Series Flow Controller
Corrosion-resistant gas flow control in continuously explosive gas atmospheres
Corrosion resistant
- 128 gas calibrations pre-loaded, including corrosives
- 0.5 SCCM – 250 SLPM
- 11.5 – 160 PSIA (high pressure option to 320 PSIA)
- Accuracy as good as ± 0.4% of reading and ± 0.2% of full scale
- See certificates below
Spec Sheets
Low Pressure Drop
ISMCW Whisper™ Series Flow Controller
Ultra-low pressure drop mass flow control in continuously explosive gas atmospheres
minimal pressure drop
- Mass flow controller
- 98 gas calibrations pre-loaded
- 0.5 SCCM – 50 SLPM
- 60 PSIA operating pressure
- Accuracy as good as ± 0.6% of reading or ± 0.1% of full scale, whichever is greater
- 0.7 PSID minimum pressure drop
- See certificates below
Spec Sheets
High pressure
ISMCQ Series Flow Controller
High pressure mass flow control in continuously explosive gas atmospheres
higher pressure
- Mass flow controller
- 98 gas calibrations pre-loaded
- 10 SCCM – 2 SLPM
- 11.5 – 320 PSIA operating pressure
- Accuracy as good as ± 0.6% of reading or ± 0.1% of full scale, whichever is greater
- See certificates below
Spec Sheets
Build Options
Calibration
Standard or high accuracy; custom calibration points
Communication Protocols
Displays
Process Connections
Ingress Protection
Hazardous Environment Ratings
Humid Gases
Relative humidity compensation, dew point reading
Ready for the final details?
Each product is made-to-order. Alicat’s Applications Engineers are ready to provide expertise and discuss custom options, ensuring the best fit for your needs.
Downloads
Manuals
Brochures
Software & utilities
Certificates
Intrinsically Safe IS-Max Flow and IS-Pro™ Pressure devices are approved for use in continuously explosive gas atmosphere hazardous locations (Class I Division 1, and Class 1 Zone 0). Looking for Class I Division 2 instead?
Certificate
Certificate Number
ATEX
IECEX
North America cDEKRAus
Top Level Part Numbers
Hidden Item So All Items Are Closed on Page Load
ISMC Controllers
ISMC-BB
ISMC-EB
ISMC-FB
ISMC-GB
ISMC-IB
ISMC-LA
ISMC-NB
ISMC-PB
ISMC-QA
ISMCS Controllers
ISMCS-BB
ISMCS-EB
ISMCS-FB
ISMCS-OA
ISMCS-QA
ISMCS-ZB
ISMCQ Controllers
ISMCQ-BB
ISMCQ-EB
ISMCQ-IB
Ask an engineer
Your flow rate, pressure, and choice of gas can all affect which Alicat instruments work for your application.
Our Applications Engineers can answer your questions and help you find the best option.