{"id":38352,"date":"2024-03-26T16:40:36","date_gmt":"2024-03-26T16:40:36","guid":{"rendered":"https:\/\/www.alicat.com\/?post_type=article&#038;p=38352"},"modified":"2026-01-26T20:52:04","modified_gmt":"2026-01-26T20:52:04","slug":"bau-von-cvd-diamantmaschinen","status":"publish","type":"support","link":"https:\/\/www.alicat.com\/de\/support\/building-cvd-diamond-machines\/","title":{"rendered":"Bau von CVD-Diamantmaschinen mit Durchfluss- und Druckregelung"},"content":{"rendered":"\n[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_row _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_heading title=&#8221;Building CVD diamond machines with flow and pressure regulation&#8221; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]In 2020, the lab-grown diamond market reached 19.3 billion dollars and by 2030 it is projected to reach about <a href=\"https:\/\/www.alliedmarketresearch.com\/lab-grown-diamonds-market-A13694\" target=\"_blank\" rel=\"noopener\">49.9 billion<\/a>. Lab-grown diamonds are safer, more environmentally friendly, and cheaper to produce than are mined diamonds.\n\nThe main methods for lab-grown diamond manufacturing are <a href=\"https:\/\/www.alicat.com\/articles\/chemical-vapor-deposition-lab-grown-diamonds\/\">HPHT and CVD<\/a>. Although HPHT developed prior to CVD, it is less commonly used since it requires more energy to operate due to its extreme temperature and pressure requirements. Moreover, HPHT is sometimes also considered as a secondary procedure to purify CVD diamonds.\n\nThe different types of CVD for diamond manufacturing include filament-assisted thermal CVD, plasma-enhanced CVD, and combustion-flame assisted CVD. Among these, a subtype of plasma-enhanced CVD, microwave plasma CVD, is the most popular and reliable.\n\nTo produce high quality lab-grown diamonds using any CVD method, manufacturers depend on Alicat\u2019s devices to ensure precise gas mixtures of hydrogen, methane, and carrier gases. In the following, we will discuss how Alicat\u2019s devices enhance each CVD process.\n<h2>Filament-assisted thermal CVD<\/h2>\nFilament-assisted thermal CVD allows for the largest lab-grown diamond growth area and a simpler design than other CVD techniques. Drawbacks include a slower diamond growth rate (0.5-8 \u00b5m\/h), and a worse process stability compared to other CVD methods.\n\nIn this configuration, methane (0.5% to 2.0%) and hydrogen gases are released in a vacuum chamber (pressurized at 10-100 Torr) and dissociated by high-melting point (2,000-2,300\u00b0C) metal filaments, typically tungsten, near a heated substrate (700-1,000\u00b0C) which accumulates diamond particles over time.\n<h3>Gas mass flow and pressure control<\/h3>\nAlicat\u2019s custom <a href=\"https:\/\/www.alicat.com\/products\/gas-flow\/mass-flow-controller\/laminar-dp-mass-flow-controllers\/\">mass flow controllers<\/a> maintain accurate gas mixing with no poisoning from atmospheric gas. With only a leak rate of 10e<sup>-9<\/sup> ATM SCCS of helium and 2 ms response times, Alicat\u2019s devices mitigate improper gas mixing and contamination of the diamond growing chamber.\n\nConnected to the chamber vacuum source, Alicat\u2019s <a href=\"https:\/\/www.alicat.com\/products\/pressure\/pressure-controller\/pressure-controllers\/\">pressure controllers<\/a> handle back pressure to allow for stable and accurate chamber conditions.\n<h2>Combustion-flame assisted CVD<\/h2>\n<a href=\"https:\/\/researchspace.auckland.ac.nz\/handle\/2292\/1251\" target=\"_blank\" rel=\"noopener\">Combustion-flame assisted CVD<\/a> grows diamonds at atmospheric pressures using an oxygen-acetylene brazing torch and water-cooled substrate. Advantages include design simplicity, good growth rates (30-100 \u00b5m\/h), and low costs.\n\nIn this setup, at sub or atmospheric pressures oxygen and acetylene gases are released into a chamber controlled by a mass flow controller where they are combusted into a 3300 K flame, producing H<sub>2<\/sub>, CO, and reactive intermediates. Outside of the main combustion area of the chamber is the feather, a flame free zone abundant in atomic hydrogen and hydrocarbon radicals where the diamond growing substrate is positioned. In the outer zone, there is a secondary combustion region which oxidizes gases to CO<sub>2<\/sub> and H<sub>2<\/sub>O. The temperature of the substrate is controlled by water flow in and out the system below a copper substrate mount using a pyrometer.\n<h3>Gas and liquid flow control<\/h3>\nAlicat mass flow controllers precisely control the gas flow of both oxygen and acetylene into the diamond growing chamber while, Alicat\u2019s liquid controllers (<a href=\"https:\/\/www.alicat.com\/products\/liquid-flow\/liquid-flow-controller\/laminar-dp-liquid-controllers\/\">LC-Series<\/a> and <a href=\"https:\/\/www.alicat.com\/products\/gas-flow\/mass-flow-controller\/gas-low-flow-coriolis-controllers\/\">CODA KC-Series<\/a>) control the flow of water to cool the diamond growing substrate.\n<ul>\n\t<li><span style=\"color: #000000;\">Gas mass flow controllers include a pneumatically actuated, positive shutoff valve to ensure no leak through and have a NIST-traceable accuracy of \u00b10.5% of reading or \u00b10.1% of full scale for 98+ gases and 20 custom-defined gas mixtures.<\/span><\/li>\n\t<li><span style=\"color: #000000;\">LC-Series liquids controllers flow 0.5 CCM to 10 LPM of water with a control response rate of just 30ms at an accuracy of \u00b12% of full scale.<\/span><\/li>\n\t<li><span style=\"color: #000000;\">CODA KC-Series Coriolis controllers can flow water from 40 g\/h to 100 kg\/h with an accuracy of only \u00b10.2% of reading or \u00b10.05% of full scale.<\/span><\/li>\n<\/ul>\n<h3>Pressure control<\/h3>\nIf operating at sub-atmospheric pressures, Alicat\u2019s pressure controllers provide stable and repeatable chamber growing conditions just as in filament-assisted thermal CVD. Custom valve sizing and PID tuning ensure that controllers reach pressure setpoints in milliseconds and maintain control with NIST-traceable accuracy to \u00b10.125% of full scale.\n<h2>Plasma-enhanced CVD<\/h2>\nMain <a href=\"https:\/\/hal.archives-ouvertes.fr\/hal-00597830\/document\" target=\"_blank\" rel=\"noopener\">plasma-enhanced CVD methods<\/a> include DC plasma jet, microwave plasma, and RF plasma. Plasma-enhanced CVD allows for better quality and stability than other CVD techniques in addition to typically faster growth rates (DC plasma jet at 930 \u00b5m\/h, microwave plasma at 3-30 \u00b5m\/h, and RF plasma at 180 \u00b5m\/h). Due to its combined large growing area and fast growth rate, microwave plasma chemical vapor deposition is currently the most practical and popular CVD technique for diamond manufacturing.\n\nIn microwave plasma chemical vapor deposition, CH<sub>4<\/sub> and H<sub>2<\/sub>, sometimes additionally with Ar, O<sub>2<\/sub>, and N<sub>2<\/sub> flow into a vacuum diamond growing chamber while high voltage microwaves hit them. These gases then turn into a plasma which reacts with the diamond growing substrate to produce diamonds.\n<h3>Pressure control<\/h3>\nVacuum pumps and pressure controllers maintain a sub-atmospheric diamond growing chamber pressure. Increasing the microwave power used in this technique causes an increase in diamond growth rates by strengthening plasma density.\n<h3>Additional info<\/h3>\nAlicat mass flow and pressure controllers are specifically customized for diamond and vacuum applications. Units built for such applications are available in 4-6 weeks with 0.25 VCRM fittings and minimal sealing surfaces in order to minimize leak points over time.\n\nFor ease of support, Alicat has<a href=\"https:\/\/www.alicat.com\/contact\/#g_tab-0-3\" rel=\"noopener\"> sales and service centers<\/a> in Surat and Thane near major diamond manufacturers.[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]\n","protected":false},"featured_media":46458,"parent":0,"template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"1920","content-type":"","_searchwp_excluded":""},"categories":[],"class_list":["post-38352","support","type-support","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.3 (Yoast SEO v27.3) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Building CVD Diamond Machines with Flow and Pressure Regulation - Alicat Scientific<\/title>\n<meta name=\"description\" content=\"It is important to calibrate a rotameter using its original calibration conditions. If a calibration lab is not easily accessible, an Alicat mass flow controller can be used to perform calibrations.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.alicat.com\/de\/unterstutzung\/bau-von-cvd-diamantmaschinen\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Building CVD Diamond Machines with Flow and Pressure Regulation\" \/>\n<meta property=\"og:description\" content=\"It is important to calibrate a rotameter using its original calibration conditions. If a calibration lab is not easily accessible, an Alicat mass flow controller can be used to perform calibrations.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.alicat.com\/de\/unterstutzung\/bau-von-cvd-diamantmaschinen\/\" \/>\n<meta property=\"og:site_name\" content=\"Alicat Scientific\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/alicatscientific\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-26T20:52:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/01\/featured-alicat.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/support\\\/building-cvd-diamond-machines\\\/\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/support\\\/building-cvd-diamond-machines\\\/\",\"name\":\"Building CVD Diamond Machines with Flow and Pressure Regulation - Alicat Scientific\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/support\\\/building-cvd-diamond-machines\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/support\\\/building-cvd-diamond-machines\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.alicat.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/featured-alicat.png\",\"datePublished\":\"2024-03-26T16:40:36+00:00\",\"dateModified\":\"2026-01-26T20:52:04+00:00\",\"description\":\"It is important to calibrate a rotameter using its original calibration conditions. If a calibration lab is not easily accessible, an Alicat mass flow controller can be used to perform calibrations.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/support\\\/building-cvd-diamond-machines\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.alicat.com\\\/support\\\/building-cvd-diamond-machines\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/support\\\/building-cvd-diamond-machines\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/featured-alicat.png\",\"contentUrl\":\"https:\\\/\\\/www.alicat.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/featured-alicat.png\",\"width\":1200,\"height\":630,\"caption\":\"Photo of an Alicat instrument with the Alicat logo behind it\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/support\\\/building-cvd-diamond-machines\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.alicat.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Building CVD Diamond Machines with Flow and Pressure Regulation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#website\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/\",\"name\":\"Alicat Scientific\",\"description\":\"Alicat Scientific | Fastest Flow Measurement Possible\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.alicat.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#organization\",\"name\":\"Alicat Scientific\",\"alternateName\":\"Alicat\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"\",\"contentUrl\":\"\",\"caption\":\"Alicat Scientific\"},\"image\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/alicatscientific\\\/\",\"https:\\\/\\\/linkedin.com\\\/company\\\/alicat-scientific-inc\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCPPX4sBOO2eEu65Zn-EfwCw\"],\"email\":\"info@alicat.com\",\"telephone\":\"+18882906060\",\"legalName\":\"Alicat Scientific, Inc.\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Bau von CVD-Diamantmaschinen mit Durchfluss- und Druckregelung - Alicat Scientific","description":"Es ist wichtig, dass ein Rotameter unter den urspr\u00fcnglichen Kalibrierbedingungen kalibriert wird. Wenn ein Kalibrierungslabor nicht leicht zug\u00e4nglich ist, kann ein Alicat-Massedurchflussregler zur Durchf\u00fchrung von Kalibrierungen verwendet werden.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.alicat.com\/de\/unterstutzung\/bau-von-cvd-diamantmaschinen\/","og_locale":"de_DE","og_type":"article","og_title":"Building CVD Diamond Machines with Flow and Pressure Regulation","og_description":"It is important to calibrate a rotameter using its original calibration conditions. If a calibration lab is not easily accessible, an Alicat mass flow controller can be used to perform calibrations.","og_url":"https:\/\/www.alicat.com\/de\/unterstutzung\/bau-von-cvd-diamantmaschinen\/","og_site_name":"Alicat Scientific","article_publisher":"https:\/\/www.facebook.com\/alicatscientific\/","article_modified_time":"2026-01-26T20:52:04+00:00","og_image":[{"width":1200,"height":630,"url":"https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/01\/featured-alicat.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.alicat.com\/support\/building-cvd-diamond-machines\/","url":"https:\/\/www.alicat.com\/support\/building-cvd-diamond-machines\/","name":"Bau von CVD-Diamantmaschinen mit Durchfluss- und Druckregelung - Alicat Scientific","isPartOf":{"@id":"https:\/\/www.alicat.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.alicat.com\/support\/building-cvd-diamond-machines\/#primaryimage"},"image":{"@id":"https:\/\/www.alicat.com\/support\/building-cvd-diamond-machines\/#primaryimage"},"thumbnailUrl":"https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/01\/featured-alicat.png","datePublished":"2024-03-26T16:40:36+00:00","dateModified":"2026-01-26T20:52:04+00:00","description":"Es ist wichtig, dass ein Rotameter unter den urspr\u00fcnglichen Kalibrierbedingungen kalibriert wird. Wenn ein Kalibrierungslabor nicht leicht zug\u00e4nglich ist, kann ein Alicat-Massedurchflussregler zur Durchf\u00fchrung von Kalibrierungen verwendet werden.","breadcrumb":{"@id":"https:\/\/www.alicat.com\/support\/building-cvd-diamond-machines\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.alicat.com\/support\/building-cvd-diamond-machines\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.alicat.com\/support\/building-cvd-diamond-machines\/#primaryimage","url":"https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/01\/featured-alicat.png","contentUrl":"https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/01\/featured-alicat.png","width":1200,"height":630,"caption":"Photo of an Alicat instrument with the Alicat logo behind it"},{"@type":"BreadcrumbList","@id":"https:\/\/www.alicat.com\/support\/building-cvd-diamond-machines\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.alicat.com\/"},{"@type":"ListItem","position":2,"name":"Building CVD Diamond Machines with Flow and Pressure Regulation"}]},{"@type":"WebSite","@id":"https:\/\/www.alicat.com\/#website","url":"https:\/\/www.alicat.com\/","name":"Alicat Scientific","description":"Alicat Scientific | Schnellstm\u00f6gliche Durchflussmessung","publisher":{"@id":"https:\/\/www.alicat.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.alicat.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.alicat.com\/#organization","name":"Alicat Scientific","alternateName":"Alicat","url":"https:\/\/www.alicat.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.alicat.com\/#\/schema\/logo\/image\/","url":"","contentUrl":"","caption":"Alicat Scientific"},"image":{"@id":"https:\/\/www.alicat.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/alicatscientific\/","https:\/\/linkedin.com\/company\/alicat-scientific-inc","https:\/\/www.youtube.com\/channel\/UCPPX4sBOO2eEu65Zn-EfwCw"],"email":"info@alicat.com","telephone":"+18882906060","legalName":"Alicat Scientific, Inc."}]}},"_links":{"self":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/support\/38352","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/support"}],"about":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/types\/support"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/media\/46458"}],"wp:attachment":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/media?parent=38352"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/categories?post=38352"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}