{"id":49035,"date":"2026-07-21T18:24:30","date_gmt":"2026-07-21T18:24:30","guid":{"rendered":"https:\/\/alicatstage.wpenginepowered.com\/?p=49035"},"modified":"2026-07-22T18:56:45","modified_gmt":"2026-07-22T18:56:45","slug":"konzeptfahrzeug-zur-demonstration-der-effizienz-von-wasserstoff-brennstoffzellen","status":"publish","type":"post","link":"https:\/\/www.alicat.com\/de\/articles\/hydrogen-fuel-cell-efficiency-concept-vehicle\/","title":{"rendered":"Wirkungsgrad von PEM-Wasserstoff-Brennstoffzellen mit Alicat-Massendurchflussregler"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_row _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;2em||0px||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_heading title=&#8221;Quantifying PEM Hydrogen Fuel Cell Efficiency with Real-Time Mass Flow Data&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; custom_css_free_form=&#8221;selector h1 {||  text-wrap: pretty;||}&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_image src=&#8221;https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/07\/utsm-hydrogen-car-on-track.webp&#8221; alt=&#8221;Photo of the UTSM hydrogen car on the racetrack&#8221; align=&#8221;center&#8221; force_fullwidth=&#8221;on&#8221; module_id=&#8221;article-hero-image&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;1.5rem||||false|false&#8221; custom_css_free_form=&#8221;selector img {||  object-fit: cover;||}&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_divider color=&#8221;#2A3B47&#8243; divider_weight=&#8221;2.5px&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; height=&#8221;0px&#8221; custom_margin=&#8221;3rem||3rem||true|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_heading title=&#8221;Acknowledgements&#8221; _builder_version=&#8221;4.27.6&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h2&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||on||||||&#8221; custom_margin=&#8221;||2rem||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]This article comes courtesy of our partners at the University of Toronto Supermileage Team. Written by Kalli Alikakos (Powertrain Lead), and Zaki Dawoodally (Technical Director), reviewed by Rafael Perez Vicente (Captain). Published July 2026.[\/et_pb_text][et_pb_divider color=&#8221;#000000&#8243; _builder_version=&#8221;4.27.5&#8243; _module_preset=&#8221;default&#8221; height=&#8221;1px&#8221; custom_margin=&#8221;||2rem||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_divider][et_pb_heading title=&#8221;What Faraday\u2019s law can\u2019t tell you about PEM fuel cell efficiency&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h2&#8243; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||2rem||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>The University of Toronto Supermileage Team competes annually in the Shell Eco-Marathon Americas, where vehicles are judged on one metric: how efficiently they complete a 16-kilometer course. Their Urban Concept entry runs on hydrogen, powered by a proton exchange membrane (PEM) fuel cell that converts hydrogen gas into the electricity driving the vehicle forward. To compete at the front of the field, the team needed to know not just how much power their fuel cell was producing, but precisely how much hydrogen it was consuming to produce it.<\/p>\n<p>[\/et_pb_text][et_pb_text admin_label=&#8221;App Note Header &#8211; Challenge&#8221; module_class=&#8221;article-section-label&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; header_2_font=&#8221;||||||||&#8221; header_2_text_color=&#8221;#808080&#8243; header_2_font_size=&#8221;28px&#8221; custom_margin=&#8221;||1rem||false|false&#8221; custom_css_free_form=&#8221;selector span {||  border-bottom: 1px solid #000;||  padding-bottom: 5px;||}&#8221; global_module=&#8221;46104&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>Challenge<\/p>\n<p>[\/et_pb_text][et_pb_heading title=&#8221;The gap in the data&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h2&#8243; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||2rem||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>Without hydrogen flow data, UTSM could track electrical output but could not calculate true efficiency, account for hydrogen lost during the fuel cell&rsquo;s automatic purge cycle, or detect performance degradation between test sessions. Prior attempts to estimate hydrogen consumption using Faraday&rsquo;s law fell short: the method relies on theoretical assumptions that do not reflect real operating conditions, and it cannot capture hydrogen vented during purging. A rotameter was also evaluated and ruled out due to poor accuracy and the absence of digital datalogging capability.<\/p>\n<p>[\/et_pb_text][et_pb_text quote_border_color=&#8221;#C11B29&#8243; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; quote_font=&#8221;||on||||||&#8221; quote_text_color=&#8221;#2A3B47&#8243; custom_margin=&#8221;||2rem||false|false&#8221; custom_css_free_form=&#8221;selector blockquote {||  background-color: #f6f6f6;||  padding: 1rem;||}&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<blockquote>\n<p>\u201cAssessing hydrogen consumption at different loads allows us to optimize our racing strategy and the design of our propulsion system.\u201d<\/p>\n<p>&nbsp;<\/p>\n<p>\u2014 University of Toronto Supermileage Team, Urban Concept Powertrain Division<\/p>\n<\/blockquote>\n<p>[\/et_pb_text][et_pb_text admin_label=&#8221;App Note Header &#8211; Selection&#8221; module_class=&#8221;article-section-label&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; header_2_font=&#8221;||||||||&#8221; header_2_text_color=&#8221;#808080&#8243; header_2_font_size=&#8221;28px&#8221; custom_margin=&#8221;||1rem||false|false&#8221; custom_css_free_form=&#8221;selector span {||  border-bottom: 1px solid #000;||  padding-bottom: 5px;||}&#8221; global_module=&#8221;46106&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>Selection<\/p>\n<p>[\/et_pb_text][et_pb_heading title=&#8221;Selecting the Alicat mass flow controller&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h2&#8243; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_image src=&#8221;https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/07\/utsm-test-bench-with-alicat.webp&#8221; alt=&#8221;Photo of the UTSM test bench with an Alicat MC Series mass flow controller&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; max_width=&#8221;50%&#8221; custom_margin=&#8221;8px||||false|false&#8221; custom_padding=&#8221;||2rem|2rem|false|false&#8221; hover_enabled=&#8221;0&#8243; custom_css_main_element=&#8221;float: right;&#8221; global_colors_info=&#8221;{}&#8221; custom_css_main_element_last_edited=&#8221;on|phone&#8221; custom_css_main_element_phone=&#8221;float: none;&#8221; custom_css_main_element_tablet=&#8221;float: right;&#8221; theme_builder_area=&#8221;post_content&#8221; max_width_last_edited=&#8221;on|phone&#8221; sticky_enabled=&#8221;0&#8243; max_width_phone=&#8221;100%&#8221; align_last_edited=&#8221;on|phone&#8221; align_phone=&#8221;center&#8221; custom_padding_last_edited=&#8221;on|phone&#8221; custom_padding_phone=&#8221;||2rem|0rem|false|false&#8221; max_width_tablet=&#8221;50%&#8221; custom_padding_tablet=&#8221;||2rem|2rem|false|false&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||2rem||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>UTSM instrumented their test bench with an Alicat MC Series mass flow controller, which uses laminar differential pressure (DP) sensing to measure mass flow, volumetric flow, temperature, and pressure simultaneously. A few characteristics of this technology suited the demands of fuel cell testing directly.<\/p>\n<p>The controller&rsquo;s wide turndown ratio meant a single instrument could cover the team&rsquo;s entire test range without swapping hardware between current steps. As the fuel cell moved from 5.0 A to 19.2 A, hydrogen flow climbed from roughly 2 SLPM to over 7 SLPM; the same controller held accuracy across that span.<\/p>\n<p>Control response as fast as 30 ms also mattered for a test protocol built around discrete load steps. Each two-minute current step required the controller to settle quickly and hold a stable reading long enough for a reliable steady-state average; a slower-responding instrument would have introduced uncertainty into the early seconds of each step.<\/p>\n<p>Built-in flow data including live flowrate, average flowrate, and a totalizer let the team capture cumulative hydrogen volume over each two-minute window directly, without separate calculation or post-processing. That totalized volume became the basis for the efficiency and utilization figures discussed below. Digital datalogging then allowed the team to store and compare results across monthly test sessions, something neither the rotameter nor the Faraday&rsquo;s law estimate could offer.<\/p>\n<p>The fuel cell was tested at five steady-state current steps from 5.0 A to 19.2 A using four 150 W load banks in constant current mode. Before each test, the stack was rehydrated at 488 W for one hour; open circuit voltage rising from 43.5 V to 46.1 V confirmed readiness. Pressure was held between 6 and 9 PSI throughout, comfortably within the controller&rsquo;s operating range.<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/07\/utsm-hydrogen-car.webp&#8221; alt=&#8221;Photo of the UTSM hydrogen car&#8221; align=&#8221;center&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; max_height=&#8221;400px&#8221; custom_margin=&#8221;2rem||2rem||true|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_text admin_label=&#8221;App Note Header &#8211; Outcomes&#8221; module_class=&#8221;article-section-label&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; header_2_font=&#8221;||||||||&#8221; header_2_text_color=&#8221;#808080&#8243; header_2_font_size=&#8221;28px&#8221; custom_margin=&#8221;||1rem||false|false&#8221; custom_css_free_form=&#8221;selector span {||  border-bottom: 1px solid #000;||  padding-bottom: 5px;||}&#8221; global_module=&#8221;46107&#8243; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>Outcomes<\/p>\n<p>[\/et_pb_text][et_pb_heading title=&#8221;Efficiency across the operating curve&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h2&#8243; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||2rem||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>With totalized hydrogen volume measured at each operating point, the team could calculate efficiency directly by comparing electrical power output against hydrogen energy input. The results revealed a clear trend: efficiency decreases as current increases, falling from 42.56% at 5.0 A to 35.03% at 19.2 A. This decline follows the drop in stack voltage across the same range and reflects the losses that accumulate at higher current densities.<\/p>\n<p>For Shell Eco-Marathon competition, the implication is direct: the fuel cell operates most efficiently at the lower end of its current range, so the optimal race strategy is to draw the minimum current needed to maintain the required vehicle speed.<\/p>\n<p>[\/et_pb_text][dvmd_table_maker tbl_description_mode=&#8221;on&#8221; tbl_description_text=&#8221;Calculated Hydrogen Utilization Ratio for the Horizon H-1000&#8243; tbl_row_header_count=&#8221;0&#8243; tbl_tcell_cell_color=&#8221;#F6F6F6&#8243; tbl_tcell_cell_align_horz=&#8221;center&#8221; tbl_tcell_cell_align_vert=&#8221;center&#8221; tbl_chead_cell_color=&#8221;#2A3B47&#8243; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; tbl_tcell_text_text_color=&#8221;#2A3B47&#8243; tbl_chead_text_font=&#8221;|600|||||||&#8221; tbl_chead_text_text_color=&#8221;#F6F6F6&#8243; custom_margin=&#8221;||2rem||false|false&#8221; hover_enabled=&#8221;0&#8243; custom_css_free_form=&#8221;selector .dvmd_tm_description {||  color: #808080;||\tfont-size: 12px;||\tfont-style: italic;||}||||selector .dvmd_tm_chead {||  overflow-wrap: break-word;||}&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221; tbl_responsive_break_by=&#8221;row&#8221; sticky_enabled=&#8221;0&#8243;][dvmd_table_maker_item col_label=&#8221;Current (A)&#8221; col_content=&#8221;Current (A)<br \/>\n5<br \/>\n10.2<br \/>\n15.3<br \/>\n18.3<br \/>\n19.2&#8243; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/dvmd_table_maker_item][dvmd_table_maker_item col_label=&#8221;Flow (SLPM)&#8221; col_content=&#8221;Flow (SLPM)<br \/>\n2.03<br \/>\n4.05<br \/>\n5.9<br \/>\n6.9<br \/>\n7.25&#8243; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/dvmd_table_maker_item][dvmd_table_maker_item col_label=&#8221;Hydrogen Consumption Rate (SLPM)&#8221; col_content=&#8221;Hydrogen Consumption Rate (SLPM)<br \/>\n2.03<br \/>\n4.05<br \/>\n5.9<br \/>\n6.9<br \/>\n7.25&#8243; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/dvmd_table_maker_item][dvmd_table_maker_item col_label=&#8221;Hydrogen Consumption Rate (mol\/s)&#8221; col_content=&#8221;Hydrogen Consumption Rate (mol\/s)<br \/>\n0.001384<br \/>\n0.002761<br \/>\n0.004022<br \/>\n0.004703<br \/>\n0.004942&#8243; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/dvmd_table_maker_item][dvmd_table_maker_item col_label=&#8221;Effective Hydrogen Consumption Rate (mol\/s)&#8221; col_content=&#8221;Effective Hydrogen Consumption Rate (mol\/s)<br \/>\n0.001244<br \/>\n0.002537<br \/>\n0.003806<br \/>\n0.004552<br \/>\n0.004775&#8243; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/dvmd_table_maker_item][dvmd_table_maker_item col_label=&#8221;Stack Utilization Ratio (%)&#8221; col_content=&#8221;Stack Utilization Ratio (%)<br \/>\n89.88%<br \/>\n91.91%<br \/>\n94.63%<br \/>\n96.79%<br \/>\n96.64%&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/dvmd_table_maker_item][\/dvmd_table_maker][et_pb_text _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||2rem||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>The Alicat totalizer also made it possible to calculate the stack&rsquo;s hydrogen utilization ratio at each operating point, comparing actual measured flow against the theoretical consumption rate derived from output current. Utilization runs at approximately 90% at low current and rises to approximately 97% at higher current densities. The remaining hydrogen exits through the purge cycle &mdash; a figure that had been invisible before flow measurement was introduced.<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; background_color=&#8221;#F6F6F6&#8243; custom_margin=&#8221;1rem||3rem||false|false&#8221; custom_padding=&#8221;2rem|3rem|2rem|3rem|true|true&#8221; border_radii=&#8221;on|18px|18px|18px|18px&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_text _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; header_3_font_size=&#8221;28px&#8221; header_2_font_tablet=&#8221;&#8221; header_2_font_phone=&#8221;&#8221; header_2_font_last_edited=&#8221;on|phone&#8221; header_2_font_size_tablet=&#8221;&#8221; header_2_font_size_phone=&#8221;&#8221; header_2_font_size_last_edited=&#8221;on|phone&#8221; header_3_font_tablet=&#8221;&#8221; header_3_font_phone=&#8221;|600|||||||&#8221; header_3_font_last_edited=&#8221;on|phone&#8221; header_3_font_size_tablet=&#8221;&#8221; header_3_font_size_phone=&#8221;18px&#8221; header_3_font_size_last_edited=&#8221;on|phone&#8221; custom_css_free_form=&#8221;selector span {||  border-bottom: 3px solid #E12028;||  padding-bottom: 5px;||}&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<h3><span>Need more details?<\/span><\/h3>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; text_font_size=&#8221;16px&#8221; custom_padding=&#8221;1rem||1rem||true|false&#8221; text_font_size_tablet=&#8221;&#8221; text_font_size_phone=&#8221;14px&#8221; text_font_size_last_edited=&#8221;on|phone&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>Download the full whitepaper for the complete dataset, efficiency calculations, and utilization analysis.<\/p>\n<p>[\/et_pb_text][et_pb_code _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<div class=\"hs-cta-embed hs-cta-simple-placeholder hs-cta-embed-216197827693\"<!-- [et_pb_line_break_holder] -->  style=&#8221;max-width:100%; max-height:100%; width:182px;height:50.37109375px; margin: 1rem auto;&#8221; data-hubspot-wrapper-cta-id=&#8221;216197827693&#8243;><!-- [et_pb_line_break_holder] -->  <a href=\"https:\/\/cta-service-cms2.hubspot.com\/web-interactives\/public\/v1\/track\/redirect?encryptedPayload=AVxigLKG40uhseTCozw68ulEFve1CVS7gSG3b4%2BRXH8xh8UH3lFeCl3WN5xo8i0X77abYtzlBtOhaxZkX0f6n%2FSF3mQ7b9j9KcQzr%2Fw9qsGULXg6w4L0qy%2F2XGdJyJd5NVEU3%2BynN%2B6dWJFRC03FKq71L4765i88SD7RrlG4RSNUtCkDQkURyXCHQECJ8RJEnA%3D%3D&#038;webInteractiveContentId=216197827693&#038;portalId=45036291\" target=\"_blank\" rel=\"noopener\" crossorigin=\"anonymous\"><!-- [et_pb_line_break_holder] -->    <img alt=\"<pee>Download PDF<\/pee>&#8221; loading=&#8221;lazy&#8221; src=&#8221;https:\/\/no-cache.hubspot.com\/cta\/default\/45036291\/interactive-216197827693.png&#8221; style=&#8221;height: 100%; width: 100%; object-fit: fill&#8221;<!-- [et_pb_line_break_holder] -->      onerror=&#8221;this.style.display=&#8217;none'&#8221; \/><!-- [et_pb_line_break_holder] -->  <\/a><!-- [et_pb_line_break_holder] --><\/div>\n<p><!-- [et_pb_line_break_holder] -->[\/et_pb_code][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;0px||0px||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_heading title=&#8221;Related products&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h2&#8243; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_4,1_4,1_4,1_4&#8243; use_custom_gutter=&#8221;on&#8221; gutter_width=&#8221;2&#8243; make_equal=&#8221;on&#8221; module_class=&#8221;row_equal_height_cards&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; custom_css_free_form=&#8221;@media (max-width: 650px) {||\t.et_pb_column {||    width: 100%!important;||\t} ||}&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column type=&#8221;1_4&#8243; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_code _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<div class=\"product_card product_card--category-page\"><!-- [et_pb_line_break_holder] -->\t<a<!-- [et_pb_line_break_holder] -->\t\thref=&#8221;https:\/\/www.alicat.com\/products\/gas-flow\/mass-flow-controller\/laminar-dp-mass-flow-controllers\/&#8221;<!-- [et_pb_line_break_holder] -->\t><!-- [et_pb_line_break_holder] -->\t\t<\/p>\n<div class=\"product_card__image\"><!-- [et_pb_line_break_holder] -->\t\t\t<img<!-- [et_pb_line_break_holder] -->\t\t\t\talt=&#8221;MC series laminar DP mass flow controllers&#8221;<!-- [et_pb_line_break_holder] -->\t\t\t\theight=&#8221;220&#8243;<!-- [et_pb_line_break_holder] -->\t\t\t\tsrc=&#8221;https:\/\/www.alicat.com\/wp-content\/uploads\/2024\/10\/MC-prod-600px.webp&#8221;<!-- [et_pb_line_break_holder] -->\t\t\t\twidth=&#8221;220&#8243;<!-- [et_pb_line_break_holder] -->\t\t\t\/><!-- [et_pb_line_break_holder] -->\t\t<\/div>\n<p><!-- [et_pb_line_break_holder] -->\t\t<\/p>\n<div class=\"product_card__headers\"><!-- [et_pb_line_break_holder] -->\t\t\t<\/p>\n<h3>Laminar DP mass flow controllers<\/h3>\n<p><!-- [et_pb_line_break_holder] -->\t\t\t<\/p>\n<h4>MC Series<\/h4>\n<p><!-- [et_pb_line_break_holder] -->      <pee>Alicat\u2019s flagship mass flow controller, used to characterize fuel cell efficiency in this study<\/pee><!-- [et_pb_line_break_holder] -->\t\t<\/div>\n<p><!-- [et_pb_line_break_holder] -->\t<\/a><!-- [et_pb_line_break_holder] --><\/div>\n<p><!-- [et_pb_line_break_holder] -->[\/et_pb_code][\/et_pb_column][et_pb_column type=&#8221;1_4&#8243; _builder_version=&#8221;4.27.3&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_code _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<div class=\"product_card product_card--category-page\"><!-- [et_pb_line_break_holder] -->\t<a<!-- [et_pb_line_break_holder] -->\t\thref=&#8221;https:\/\/www.alicat.com\/products\/gas-flow\/mass-flow-controller\/low-pressure-drop-mass-flow-controllers\/&#8221;<!-- [et_pb_line_break_holder] -->\t><!-- [et_pb_line_break_holder] -->\t\t<\/p>\n<div class=\"product_card__image\"><!-- [et_pb_line_break_holder] -->\t\t\t<img<!-- [et_pb_line_break_holder] -->\t\t\t\talt=&#8221;Alicat Low Pressure Drop Mass Flow Controller&#8221;<!-- [et_pb_line_break_holder] -->\t\t\t\theight=&#8221;220&#8243;<!-- [et_pb_line_break_holder] -->\t\t\t\tsrc=&#8221;https:\/\/www.alicat.com\/wp-content\/uploads\/2024\/10\/MCW-prod-600px.webp&#8221;<!-- [et_pb_line_break_holder] -->\t\t\t\twidth=&#8221;220&#8243;<!-- [et_pb_line_break_holder] -->\t\t\t\/><!-- [et_pb_line_break_holder] -->\t\t<\/div>\n<p><!-- [et_pb_line_break_holder] -->\t\t<\/p>\n<div class=\"product_card__headers\"><!-- [et_pb_line_break_holder] -->\t\t\t<\/p>\n<h3>Mass flow controller with minimal pressure drop<\/h3>\n<p><!-- [et_pb_line_break_holder] -->\t\t\t<\/p>\n<h4>MCW Series<\/h4>\n<p><!-- [et_pb_line_break_holder] -->      <pee>High resolution mass flow controller with reduced pressure differential <\/pee><!-- [et_pb_line_break_holder] -->\t\t<\/div>\n<p><!-- [et_pb_line_break_holder] -->\t<\/a><!-- [et_pb_line_break_holder] --><\/div>\n<p><!-- [et_pb_line_break_holder] -->[\/et_pb_code][\/et_pb_column][et_pb_column type=&#8221;1_4&#8243; _builder_version=&#8221;4.27.3&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_code _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<div class=\"product_card product_card--category-page\"><!-- [et_pb_line_break_holder] -->\t<a<!-- [et_pb_line_break_holder] -->\t\thref=&#8221;https:\/\/www.alicat.com\/products\/gas-flow\/mass-flow-controller\/class-i-div-1-flow-controllers\/&#8221;<!-- [et_pb_line_break_holder] -->\t><!-- [et_pb_line_break_holder] -->\t\t<\/p>\n<div class=\"product_card__image\"><!-- [et_pb_line_break_holder] -->\t\t\t<img<!-- [et_pb_line_break_holder] -->\t\t\t\talt=&#8221;Alicat Intrinsically Safe Mass Flow Controller&#8221;<!-- [et_pb_line_break_holder] -->\t\t\t\theight=&#8221;220&#8243;<!-- [et_pb_line_break_holder] -->\t\t\t\tsrc=&#8221;https:\/\/www.alicat.com\/wp-content\/uploads\/2024\/10\/ISMC-prod-600px.webp&#8221;<!-- [et_pb_line_break_holder] -->\t\t\t\twidth=&#8221;220&#8243;<!-- [et_pb_line_break_holder] -->\t\t\t\/><!-- [et_pb_line_break_holder] -->\t\t<\/div>\n<p><!-- [et_pb_line_break_holder] -->\t\t<\/p>\n<div class=\"product_card__headers\"><!-- [et_pb_line_break_holder] -->\t\t\t<\/p>\n<h3>CID1-rated mass flow controller<\/h3>\n<p><!-- [et_pb_line_break_holder] -->\t\t\t<\/p>\n<h4>IS-Max\u2122 ISMC<\/h4>\n<p><!-- [et_pb_line_break_holder] -->      <pee>Intrinsically safe laminar DP controller, with humidity compensation for steamy processes<\/pee><!-- [et_pb_line_break_holder] -->\t\t<\/div>\n<p><!-- [et_pb_line_break_holder] -->\t<\/a><!-- [et_pb_line_break_holder] --><\/div>\n<p><!-- [et_pb_line_break_holder] -->[\/et_pb_code][\/et_pb_column][et_pb_column type=&#8221;1_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_code _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<div class=\"product_card product_card--category-page\"><!-- [et_pb_line_break_holder] -->\t<a<!-- [et_pb_line_break_holder] -->\t\thref=&#8221;https:\/\/www.alicat.com\/products\/pressure\/pressure-controller\/class-i-div-1-pressure-controllers\/&#8221;<!-- [et_pb_line_break_holder] -->\t><!-- [et_pb_line_break_holder] -->\t\t<\/p>\n<div class=\"product_card__image\"><!-- [et_pb_line_break_holder] -->\t\t\t<img<!-- [et_pb_line_break_holder] -->\t\t\t\talt=&#8221;Alicat Intrinsically Safe Pressure Controller&#8221;<!-- [et_pb_line_break_holder] -->\t\t\t\theight=&#8221;220&#8243;<!-- [et_pb_line_break_holder] -->\t\t\t\tsrc=&#8221;https:\/\/www.alicat.com\/wp-content\/uploads\/2024\/10\/ISPC-prod-600px.webp&#8221;<!-- [et_pb_line_break_holder] -->\t\t\t\twidth=&#8221;220&#8243;<!-- [et_pb_line_break_holder] -->\t\t\t\/><!-- [et_pb_line_break_holder] -->\t\t<\/div>\n<p><!-- [et_pb_line_break_holder] -->\t\t<\/p>\n<div class=\"product_card__headers\"><!-- [et_pb_line_break_holder] -->\t\t\t<\/p>\n<h3>CID1-rated electronic pressure controller<\/h3>\n<p><!-- [et_pb_line_break_holder] -->\t\t\t<\/p>\n<h4>IS-Pro\u2122 ISPC<\/h4>\n<p><!-- [et_pb_line_break_holder] -->      <pee>Intrinsically safe pressure controller for PEM applications where hydrogen gases cause safety risk<\/pee><!-- [et_pb_line_break_holder] -->\t\t<\/div>\n<p><!-- [et_pb_line_break_holder] -->\t<\/a><!-- [et_pb_line_break_holder] --><\/div>\n<p><!-- [et_pb_line_break_holder] -->[\/et_pb_code][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_text module_class=&#8221;cta-link&#8221; _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;|700|||||||&#8221; custom_margin=&#8221;1rem||2rem||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<a href=\"https:\/\/www.alicat.com\/articles\/verifying-h2-electrolyzer-flow\/\">Keep reading: Safe PEM electrolysis in hazardous zones <span class=\"et-pb-icon link-right-arrow\">$<\/span><\/a>[\/et_pb_text][et_pb_divider color=&#8221;#000000&#8243; _builder_version=&#8221;4.27.5&#8243; _module_preset=&#8221;default&#8221; height=&#8221;1px&#8221; custom_margin=&#8221;||2rem||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_divider][et_pb_heading title=&#8221;References&#8221; _builder_version=&#8221;4.27.6&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h2&#8243; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.27.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; custom_margin=&#8221;||2rem||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<ul>\n<li>Alikakos, K., &#038; Dawoodally, Z. (2026). <em>Assessing proton exchange membrane hydrogen fuel cell performance with Alicat flowmeter to determine its practical efficiency.<\/em> University of Toronto Supermileage Team. Reviewed by R. Perez Vicente.<\/li>\n<\/ul>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This article comes courtesy of our partners at the University of Toronto Supermileage Team. Written by Kalli Alikakos (Powertrain Lead), and Zaki Dawoodally (Technical Director), reviewed by Rafael Perez Vicente (Captain). Published July 2026.The University of Toronto Supermileage Team competes annually in the Shell Eco-Marathon Americas, where vehicles are judged on one metric: how efficiently [&hellip;]<\/p>\n","protected":false},"author":24,"featured_media":49077,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","content-type":"","_searchwp_excluded":"","footnotes":""},"categories":[147,120,115,131,152,168],"tags":[],"class_list":["post-49035","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-energy","category-hydrogen","category-mass-flow","category-mass-flow-controllers","category-mc-series","category-research-laboratories-industry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.1 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>PEM Hydrogen Fuel Cell Efficiency with Alicat Mass Flow Controller - Alicat Scientific<\/title>\n<meta name=\"description\" content=\"See how the University of Toronto Supermileage Team used an Alicat mass flow controller to quantify PEM hydrogen fuel cell efficiency and optimize their racing strategy.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.alicat.com\/de\/artikel\/konzeptfahrzeug-zur-demonstration-der-effizienz-von-wasserstoff-brennstoffzellen\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PEM Hydrogen Fuel Cell Efficiency with Alicat Mass Flow Controller\" \/>\n<meta property=\"og:description\" content=\"See how the University of Toronto Supermileage Team used an Alicat mass flow controller to quantify PEM hydrogen fuel cell efficiency and optimize their racing strategy.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.alicat.com\/de\/artikel\/konzeptfahrzeug-zur-demonstration-der-effizienz-von-wasserstoff-brennstoffzellen\/\" \/>\n<meta property=\"og:site_name\" content=\"Alicat Scientific\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/alicatscientific\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-21T18:24:30+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-22T18:56:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/07\/utsm-hydrogen-car-on-track-featured.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Jarod Kober\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jarod Kober\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/hydrogen-fuel-cell-efficiency-concept-vehicle\\\/\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/hydrogen-fuel-cell-efficiency-concept-vehicle\\\/\",\"name\":\"PEM Hydrogen Fuel Cell Efficiency with Alicat Mass Flow Controller - Alicat Scientific\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/hydrogen-fuel-cell-efficiency-concept-vehicle\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/hydrogen-fuel-cell-efficiency-concept-vehicle\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.alicat.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/utsm-hydrogen-car-on-track-featured.webp\",\"datePublished\":\"2026-07-21T18:24:30+00:00\",\"dateModified\":\"2026-07-22T18:56:45+00:00\",\"description\":\"See how the University of Toronto Supermileage Team used an Alicat mass flow controller to quantify PEM hydrogen fuel cell efficiency and optimize their racing strategy.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/hydrogen-fuel-cell-efficiency-concept-vehicle\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.alicat.com\\\/articles\\\/hydrogen-fuel-cell-efficiency-concept-vehicle\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/hydrogen-fuel-cell-efficiency-concept-vehicle\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/utsm-hydrogen-car-on-track-featured.webp\",\"contentUrl\":\"https:\\\/\\\/www.alicat.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/utsm-hydrogen-car-on-track-featured.webp\",\"width\":1200,\"height\":630,\"caption\":\"Photo of the UTSM hydrogen car on the racetrack\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/hydrogen-fuel-cell-efficiency-concept-vehicle\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.alicat.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PEM Hydrogen Fuel Cell Efficiency with Alicat Mass Flow Controller\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#website\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/\",\"name\":\"Alicat Scientific\",\"description\":\"Alicat Scientific | Fastest Flow Measurement Possible\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.alicat.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#organization\",\"name\":\"Alicat Scientific\",\"alternateName\":\"Alicat\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"\",\"contentUrl\":\"\",\"caption\":\"Alicat Scientific\"},\"image\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/alicatscientific\\\/\",\"https:\\\/\\\/linkedin.com\\\/company\\\/alicat-scientific-inc\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCPPX4sBOO2eEu65Zn-EfwCw\"],\"email\":\"info@alicat.com\",\"telephone\":\"+18882906060\",\"legalName\":\"Alicat Scientific, Inc.\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Wirkungsgrad von PEM-Wasserstoff-Brennstoffzellen mit Alicat-Massendurchflussreglern \u2013 Alicat Scientific","description":"Erfahren Sie, wie das \u201eSupermileage\u201c-Team der University of Toronto mithilfe eines Alicat-Massendurchflussreglers den Wirkungsgrad einer PEM-Wasserstoff-Brennstoffzelle ermittelt und seine Rennstrategie optimiert hat.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.alicat.com\/de\/artikel\/konzeptfahrzeug-zur-demonstration-der-effizienz-von-wasserstoff-brennstoffzellen\/","og_locale":"de_DE","og_type":"article","og_title":"PEM Hydrogen Fuel Cell Efficiency with Alicat Mass Flow Controller","og_description":"See how the University of Toronto Supermileage Team used an Alicat mass flow controller to quantify PEM hydrogen fuel cell efficiency and optimize their racing strategy.","og_url":"https:\/\/www.alicat.com\/de\/artikel\/konzeptfahrzeug-zur-demonstration-der-effizienz-von-wasserstoff-brennstoffzellen\/","og_site_name":"Alicat Scientific","article_publisher":"https:\/\/www.facebook.com\/alicatscientific\/","article_published_time":"2026-07-21T18:24:30+00:00","article_modified_time":"2026-07-22T18:56:45+00:00","og_image":[{"width":1200,"height":630,"url":"https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/07\/utsm-hydrogen-car-on-track-featured.webp","type":"image\/webp"}],"author":"Jarod Kober","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Jarod Kober","Est. reading time":"5\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.alicat.com\/articles\/hydrogen-fuel-cell-efficiency-concept-vehicle\/","url":"https:\/\/www.alicat.com\/articles\/hydrogen-fuel-cell-efficiency-concept-vehicle\/","name":"Wirkungsgrad von PEM-Wasserstoff-Brennstoffzellen mit Alicat-Massendurchflussreglern \u2013 Alicat Scientific","isPartOf":{"@id":"https:\/\/www.alicat.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.alicat.com\/articles\/hydrogen-fuel-cell-efficiency-concept-vehicle\/#primaryimage"},"image":{"@id":"https:\/\/www.alicat.com\/articles\/hydrogen-fuel-cell-efficiency-concept-vehicle\/#primaryimage"},"thumbnailUrl":"https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/07\/utsm-hydrogen-car-on-track-featured.webp","datePublished":"2026-07-21T18:24:30+00:00","dateModified":"2026-07-22T18:56:45+00:00","description":"Erfahren Sie, wie das \u201eSupermileage\u201c-Team der University of Toronto mithilfe eines Alicat-Massendurchflussreglers den Wirkungsgrad einer PEM-Wasserstoff-Brennstoffzelle ermittelt und seine Rennstrategie optimiert hat.","breadcrumb":{"@id":"https:\/\/www.alicat.com\/articles\/hydrogen-fuel-cell-efficiency-concept-vehicle\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.alicat.com\/articles\/hydrogen-fuel-cell-efficiency-concept-vehicle\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.alicat.com\/articles\/hydrogen-fuel-cell-efficiency-concept-vehicle\/#primaryimage","url":"https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/07\/utsm-hydrogen-car-on-track-featured.webp","contentUrl":"https:\/\/www.alicat.com\/wp-content\/uploads\/2026\/07\/utsm-hydrogen-car-on-track-featured.webp","width":1200,"height":630,"caption":"Photo of the UTSM hydrogen car on the racetrack"},{"@type":"BreadcrumbList","@id":"https:\/\/www.alicat.com\/articles\/hydrogen-fuel-cell-efficiency-concept-vehicle\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.alicat.com\/"},{"@type":"ListItem","position":2,"name":"PEM Hydrogen Fuel Cell Efficiency with Alicat Mass Flow Controller"}]},{"@type":"WebSite","@id":"https:\/\/www.alicat.com\/#website","url":"https:\/\/www.alicat.com\/","name":"Alicat Scientific","description":"Alicat Scientific | Schnellstm\u00f6gliche Durchflussmessung","publisher":{"@id":"https:\/\/www.alicat.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.alicat.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.alicat.com\/#organization","name":"Alicat Scientific","alternateName":"Alicat","url":"https:\/\/www.alicat.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.alicat.com\/#\/schema\/logo\/image\/","url":"","contentUrl":"","caption":"Alicat Scientific"},"image":{"@id":"https:\/\/www.alicat.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/alicatscientific\/","https:\/\/linkedin.com\/company\/alicat-scientific-inc","https:\/\/www.youtube.com\/channel\/UCPPX4sBOO2eEu65Zn-EfwCw"],"email":"info@alicat.com","telephone":"+18882906060","legalName":"Alicat Scientific, Inc."}]}},"_links":{"self":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/posts\/49035","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/users\/24"}],"replies":[{"embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/comments?post=49035"}],"version-history":[{"count":34,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/posts\/49035\/revisions"}],"predecessor-version":[{"id":49118,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/posts\/49035\/revisions\/49118"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/media\/49077"}],"wp:attachment":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/media?parent=49035"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/categories?post=49035"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/tags?post=49035"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}