{"id":45899,"date":"2025-11-12T18:48:27","date_gmt":"2025-11-12T18:48:27","guid":{"rendered":"https:\/\/www.alicat.com\/?p=45899"},"modified":"2026-01-06T22:18:34","modified_gmt":"2026-01-06T22:18:34","slug":"brennerprufung-mit-gasmischern","status":"publish","type":"post","link":"https:\/\/www.alicat.com\/de\/articles\/burner-testing-with-gas-mixers\/","title":{"rendered":"Brennerpr\u00fcfung mit einem Pr\u00e4zisionsgasmischer"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_row _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;2em||0px||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_heading title=&#8221;Burner Testing with a Precision Gas Blender&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_css_free_form=&#8221;selector h1 {||  text-wrap: pretty;||}&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_image src=&#8221;https:\/\/www.alicat.com\/wp-content\/uploads\/2025\/11\/burner-test.webp&#8221; alt=&#8221;blue gas burner&#8221; align=&#8221;center&#8221; force_fullwidth=&#8221;on&#8221; _builder_version=&#8221;4.27.5&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;1.5rem||||false|false&#8221; hover_enabled=&#8221;0&#8243; custom_css_free_form=&#8221;selector img {||  object-fit: cover;||}&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221; sticky_enabled=&#8221;0&#8243; module_id=&#8221;article-hero-image&#8221;][\/et_pb_image][et_pb_divider color=&#8221;#2A3B47&#8243; divider_weight=&#8221;2.5px&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; height=&#8221;0px&#8221; custom_margin=&#8221;3rem||3rem||true|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||2rem||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>Burner manufacturers and appliance producers are required to verify that their equipment operates safely, efficiently, and within emissions limits across the range of fuels it may encounter in the field. Certification bodies such as CSA establish testing protocols to confirm that burners maintain stable flame behavior, ignition reliability, and combustion characteristics under varying gas compositions and supply pressures.<\/p>\n<p>Accurate testing depends on the ability to reproduce those fuel properties and flow conditions in a controlled environment. Each test must reflect the correct heating value, air-to-fuel ratio, and specific gravity of the target gas. Reliable results allow engineers and certifying agencies to evaluate burner performance and confirm compliance before products are released for commercial use.<\/p>\n<p>[\/et_pb_text][et_pb_heading title=&#8221;Challenges in burner testing&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h3&#8243; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||2rem||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>Appliance manufacturers and test facilities commonly use pre-mixed gas cylinders for burner evaluation. Cylinders provide a fixed blend that cannot be changed once delivered, which limits test flexibility. Each gas blend must be ordered separately, and empty cylinders accumulate quickly. Managing storage and disposal becomes a logistical burden that can add cost, administrative work, and unnecessary bulk in the test area while slowing down testing times.\u00a0<\/p>\n<p>During cyclic burner operation, supply-pressure changes can alter flow and mixture ratios at the burner. These variations affect flame shape, temperature, and emissions data, reducing test repeatability. Manual blending with rotameters or valves offers limited correction and increases both uncertainty in composition and operator exposure to gas.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; module_alignment=&#8221;center&#8221; custom_margin=&#8221;||0px||false|false&#8221; custom_padding=&#8221;||2rem||false|false&#8221; custom_padding_last_edited=&#8221;off|desktop&#8221; custom_css_free_form=&#8221;selector figure {||  display: table;||  margin-left: auto;||  margin-right: auto;||  text-align: center;||}||||selector figcaption {||  caption-side: bottom;||  display: table-caption;||}||||selector img {||  margin-bottom: 1rem;||}&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; custom_css_main_element_last_edited=&#8221;on|phone&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/www.alicat.com\/wp-content\/uploads\/2025\/10\/mxm-burner-fullsize-1024x384.webp\" width=\"1024\" height=\"384\" alt=\"MXM burner testing\" class=\"wp-image-45996 alignnone size-large\" srcset=\"https:\/\/www.alicat.com\/wp-content\/uploads\/2025\/10\/mxm-burner-fullsize-980x368.webp 980w, https:\/\/www.alicat.com\/wp-content\/uploads\/2025\/10\/mxm-burner-fullsize-480x180.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p><figcaption>FusionFlow MXM gas blender receiving four different gases and producing a dynamic gas mix<\/figcaption><\/figure>\n<p>[\/et_pb_text][et_pb_heading title=&#8221;Custom gas mixing for CSA certification&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h3&#8243; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_image src=&#8221;https:\/\/www.alicat.com\/wp-content\/uploads\/2025\/11\/FusionFlow-MXM-vs-premixed-cylinders-graphic.webp&#8221; alt=&#8221;FusionFlow MXM vs premixed cylinders graphic&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;center&#8221; align_last_edited=&#8221;on|tablet&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; max_width=&#8221;50%&#8221; max_width_tablet=&#8221;80%&#8221; max_width_phone=&#8221;100%&#8221; max_width_last_edited=&#8221;on|phone&#8221; custom_margin_tablet=&#8221;1rem||||false|false&#8221; custom_margin_phone=&#8221;1rem||||false|false&#8221; custom_margin_last_edited=&#8221;on|tablet&#8221; custom_padding=&#8221;||2rem|2rem|false|false&#8221; custom_padding_tablet=&#8221;||2rem|0rem|false|false&#8221; custom_padding_phone=&#8221;||2rem|0rem|false|false&#8221; custom_padding_last_edited=&#8221;on|tablet&#8221; custom_css_main_element=&#8221;float: right;&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; custom_css_main_element_last_edited=&#8221;on|tablet&#8221; custom_css_main_element_tablet=&#8221;float: none;&#8221; custom_css_main_element_phone=&#8221;float: none;&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||2rem||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]A manufacturer conducting CSA certification tests integrated a\u00a0<a href=\"https:\/\/www.alicat.com\/products\/gas-flow\/gas-mixer\/gas-blending-system\/\">FusionFlow&trade; MXM gas-blender<\/a> into their test system to supply a premixed air\u2013fuel stream to the burners. The setup required precise blending of combustible gases such as hydrogen (H<sub>2<\/sub>), butane (C<sub>4<\/sub>H<sub>10<\/sub>), methane (CH<sub>4<\/sub>), carbon monoxide (CO), and carbon dioxide (CO<sub>2<\/sub>) to simulate various regional and experimental fuel compositions.<\/p>\n<p>To maintain accurate mixture ratios during burner cycling, the MXM provided closed-loop composition control with automatic compensation for inlet and outlet pressure changes. The integrated Alicat mass flow controllers allowed researchers to quickly switch between test gases, with 25 ms control response and access to <a href=\"https:\/\/www.alicat.com\/documentation\/gas-select-gas-list\/#fusionflow-gas-list\">49 selectable gas calibrations from an onboard library<\/a>.<\/p>\n<p>Safety limits within the system prevented stoichiometric or otherwise unsafe mixtures. Remote configuration allowed operation from outside the test area, minimizing handling of fuel gases and simplifying setup during certification runs.<\/p>\n<p>The MXM&rsquo;s interactive HMI displayed real-time flow, pressure, and blend composition. Engineers could adjust setpoints, monitor stability, and log performance data directly through the interface. Its compact, modular layout fit easily on existing test benches or carts commonly used in burner validation.<\/p>\n<p>With the MXM in place, the team produced custom gas blends on demand, adjusted mixture ratios between test points, and maintained stable flow throughout repeated test cycles. Inline analyzers verified composition accuracy, and flame characteristics confirmed consistent burner operation across all test conditions.[\/et_pb_text][et_pb_heading title=&#8221;Observed Results&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h3&#8243; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||2rem||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<ul>\n<li>Stable flow maintained during burner cycling<\/li>\n<li>No measurable drift over multiple days of continuous operation<\/li>\n<li>Blend accuracy confirmed by gas analysis and flame behavior<\/li>\n<li>Safe remote operation with automatic mixture protection<\/li>\n<\/ul>\n<p>[\/et_pb_text][et_pb_heading title=&#8221;Summary&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; title_level=&#8221;h3&#8243; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_heading][et_pb_text _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||2rem||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>Precise gas control is essential for reliable burner testing. Stable mixture ratios allow engineers to compare burner behavior across multiple operating conditions without interference from gas-supply variability.<\/p>\n<p>Using FusionFlow MXM, fuel composition and flow remained constant during repeated test cycles. The closed-loop system eliminated drift and flow imbalance often seen with pre-mixed cylinders or manual blending. Consistent test conditions produced repeatable flame and emissions data suitable for certification review.<\/p>\n<p>[\/et_pb_text][et_pb_text module_class=&#8221;cta-link&#8221; _builder_version=&#8221;4.27.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;|700|||||||&#8221; custom_margin=&#8221;||2rem||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<a href=\"https:\/\/www.alicat.com\/products\/fusionflow\/\">Learn more about FusionFlow gas blending capabilities <span class=\"et-pb-icon link-right-arrow\">$<\/span><\/a>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Burner manufacturers and appliance producers are required to verify that their equipment operates safely, efficiently, and within emissions limits across the range of fuels it may encounter in the field. Certification bodies such as CSA establish testing protocols to confirm that burners maintain stable flame behavior, ignition reliability, and combustion characteristics under varying gas compositions [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":46079,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","content-type":"","_searchwp_excluded":"","footnotes":""},"categories":[110],"tags":[],"class_list":["post-45899","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-fusionflow"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.5 (Yoast SEO v27.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Burner Testing with a Precision Gas Mixer - Alicat Scientific<\/title>\n<meta name=\"description\" content=\"CSA certification requires precise control of gases within burner testing applications, the FusionFlow MXM excels in precise control needed for burner testing.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.alicat.com\/de\/artikel\/brennerprufung-mit-gasmischern\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Burner Testing with a Precision Gas Mixer\" \/>\n<meta property=\"og:description\" content=\"CSA certification requires precise control of gases within burner testing applications, the FusionFlow MXM excels in precise control needed for burner testing.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.alicat.com\/de\/artikel\/brennerprufung-mit-gasmischern\/\" \/>\n<meta property=\"og:site_name\" content=\"Alicat Scientific\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/alicatscientific\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-11-12T18:48:27+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-06T22:18:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.alicat.com\/wp-content\/uploads\/2025\/11\/burner-test.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"2400\" \/>\n\t<meta property=\"og:image:height\" content=\"906\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Alicat Scientific\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alicat Scientific\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/burner-testing-with-gas-mixers\\\/\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/burner-testing-with-gas-mixers\\\/\",\"name\":\"Burner Testing with a Precision Gas Mixer - Alicat Scientific\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/burner-testing-with-gas-mixers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/burner-testing-with-gas-mixers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.alicat.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/burner-test.webp\",\"datePublished\":\"2025-11-12T18:48:27+00:00\",\"dateModified\":\"2026-01-06T22:18:34+00:00\",\"description\":\"CSA certification requires precise control of gases within burner testing applications, the FusionFlow MXM excels in precise control needed for burner testing.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/burner-testing-with-gas-mixers\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.alicat.com\\\/articles\\\/burner-testing-with-gas-mixers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/burner-testing-with-gas-mixers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/burner-test.webp\",\"contentUrl\":\"https:\\\/\\\/www.alicat.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/burner-test.webp\",\"width\":2400,\"height\":906,\"caption\":\"blue gas burner\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/articles\\\/burner-testing-with-gas-mixers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.alicat.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Burner Testing with a Precision Gas Mixer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#website\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/\",\"name\":\"Alicat Scientific\",\"description\":\"Alicat Scientific | Fastest Flow Measurement Possible\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.alicat.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#organization\",\"name\":\"Alicat Scientific\",\"alternateName\":\"Alicat\",\"url\":\"https:\\\/\\\/www.alicat.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"\",\"contentUrl\":\"\",\"caption\":\"Alicat Scientific\"},\"image\":{\"@id\":\"https:\\\/\\\/www.alicat.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/alicatscientific\\\/\",\"https:\\\/\\\/linkedin.com\\\/company\\\/alicat-scientific-inc\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCPPX4sBOO2eEu65Zn-EfwCw\"],\"email\":\"info@alicat.com\",\"telephone\":\"+18882906060\",\"legalName\":\"Alicat Scientific, Inc.\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Brennerpr\u00fcfung mit einem Pr\u00e4zisionsgasmischer - Alicat Scientific","description":"Die CSA-Zertifizierung erfordert eine pr\u00e4zise Steuerung von Gasen bei Brennertestanwendungen. Das FusionFlow MXM zeichnet sich durch die f\u00fcr Brennertests erforderliche pr\u00e4zise Steuerung aus.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.alicat.com\/de\/artikel\/brennerprufung-mit-gasmischern\/","og_locale":"de_DE","og_type":"article","og_title":"Burner Testing with a Precision Gas Mixer","og_description":"CSA certification requires precise control of gases within burner testing applications, the FusionFlow MXM excels in precise control needed for burner testing.","og_url":"https:\/\/www.alicat.com\/de\/artikel\/brennerprufung-mit-gasmischern\/","og_site_name":"Alicat Scientific","article_publisher":"https:\/\/www.facebook.com\/alicatscientific\/","article_published_time":"2025-11-12T18:48:27+00:00","article_modified_time":"2026-01-06T22:18:34+00:00","og_image":[{"width":2400,"height":906,"url":"https:\/\/www.alicat.com\/wp-content\/uploads\/2025\/11\/burner-test.webp","type":"image\/webp"}],"author":"Alicat Scientific","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alicat Scientific","Est. reading time":"4\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.alicat.com\/articles\/burner-testing-with-gas-mixers\/","url":"https:\/\/www.alicat.com\/articles\/burner-testing-with-gas-mixers\/","name":"Brennerpr\u00fcfung mit einem Pr\u00e4zisionsgasmischer - Alicat Scientific","isPartOf":{"@id":"https:\/\/www.alicat.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.alicat.com\/articles\/burner-testing-with-gas-mixers\/#primaryimage"},"image":{"@id":"https:\/\/www.alicat.com\/articles\/burner-testing-with-gas-mixers\/#primaryimage"},"thumbnailUrl":"https:\/\/www.alicat.com\/wp-content\/uploads\/2025\/11\/burner-test.webp","datePublished":"2025-11-12T18:48:27+00:00","dateModified":"2026-01-06T22:18:34+00:00","description":"Die CSA-Zertifizierung erfordert eine pr\u00e4zise Steuerung von Gasen bei Brennertestanwendungen. Das FusionFlow MXM zeichnet sich durch die f\u00fcr Brennertests erforderliche pr\u00e4zise Steuerung aus.","breadcrumb":{"@id":"https:\/\/www.alicat.com\/articles\/burner-testing-with-gas-mixers\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.alicat.com\/articles\/burner-testing-with-gas-mixers\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.alicat.com\/articles\/burner-testing-with-gas-mixers\/#primaryimage","url":"https:\/\/www.alicat.com\/wp-content\/uploads\/2025\/11\/burner-test.webp","contentUrl":"https:\/\/www.alicat.com\/wp-content\/uploads\/2025\/11\/burner-test.webp","width":2400,"height":906,"caption":"blue gas burner"},{"@type":"BreadcrumbList","@id":"https:\/\/www.alicat.com\/articles\/burner-testing-with-gas-mixers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.alicat.com\/"},{"@type":"ListItem","position":2,"name":"Burner Testing with a Precision Gas Mixer"}]},{"@type":"WebSite","@id":"https:\/\/www.alicat.com\/#website","url":"https:\/\/www.alicat.com\/","name":"Alicat Scientific","description":"Alicat Scientific | Schnellstm\u00f6gliche Durchflussmessung","publisher":{"@id":"https:\/\/www.alicat.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.alicat.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.alicat.com\/#organization","name":"Alicat Scientific","alternateName":"Alicat","url":"https:\/\/www.alicat.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.alicat.com\/#\/schema\/logo\/image\/","url":"","contentUrl":"","caption":"Alicat Scientific"},"image":{"@id":"https:\/\/www.alicat.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/alicatscientific\/","https:\/\/linkedin.com\/company\/alicat-scientific-inc","https:\/\/www.youtube.com\/channel\/UCPPX4sBOO2eEu65Zn-EfwCw"],"email":"info@alicat.com","telephone":"+18882906060","legalName":"Alicat Scientific, Inc."}]}},"_links":{"self":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/posts\/45899","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/comments?post=45899"}],"version-history":[{"count":0,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/posts\/45899\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/media\/46079"}],"wp:attachment":[{"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/media?parent=45899"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/categories?post=45899"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.alicat.com\/de\/wp-json\/wp\/v2\/tags?post=45899"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}