CSA Approved
For Class 1 Division 2 hazardous environments
Alicat Scientific’s CSA approved hazardous environment (-X) option was designed to be used in hazardous environments where it will not be a source of ignition.
Fully functional digital display
Alicat’s digital display allows users to monitor the following parameters in real time:
- flow
- temperature
- pressure
The display also allows the user to make functional changes to the unit like changing the measured gas, set point control and taring without the need for digital communication or special software.
Full featured
Often times, Class 1 Div 2 approved devices are stripped of all “unnecessary” functionality to reduce power consumption and creation of heat. The Alicat device, by it’s nature, consumes very little power and as such was able to comply with Class 1 Div 2 requirements with the display intact. This allows users of this device in hazardous environments the flexibilty of having an on-board display for quick visual verification of mass flow meter or mass flow controller operation.
Versatility
The Alicat Class 1 Div 2 approved -X option can be added to most of the Alicat family of flow and pressure products.
Standard Features
- Fully functional digital display
- Multiple parameter measurement: Mass flow, volumetric flow, temperature, and pressure
- Low pressure drop operation
- No warm up time
- Viton seals
- 6 pin locking electronic connector
- RS-232 Multi-drop digital output
- RS-232 Multi-drop digital input (controllers only)
- Choice of 0-5Vdc, 0-10Vdc, or 1-5Vdc analog output
- Choice of 0-5Vdc, 0-10Vdc, 1-5Vdc, or 4-20mA analog input (controllers only)
- User tunable PID valve tuning (controllers only)
- 30 user selectable on-board gas calibrations
- 200:1 turndown ratio
- NPT process connections
- Can be ordered in any flow range between 0.5SCCM and 3000SLPM (2000SLPM for controllers)
- Lifetime warranty
Optional features and equipment
- High accuracy calibration
- Flow totalizer
- 4-20mA analog output
- Secondary analog output (meters only)
- Acrylic Mil-spec dielectric conformal coating
- EPDM seals
- NeSSI flow body
- Oxygen cleaned
- SAE process connections
- VCR, VCO style welded fittings
- Bi-directional flow
- Additional calibration points
- Custom gas blends with up to 4 gases
- Custom mass based flow range
- Stainless steel valves (controllers only)
- High flow, low drop valve (controllers only)
- Air
- Argon
- Methane
- Carbon Dioxide
- Carbon Monoxide
- Ethane
- Hydrogen
- Helium
- Nitrogen
- Nitrous Oxide
- Neon
- Oxygen
- Propane
- n-Butane
- Acetylene
- Ethylene
- iso-Butane
- Krypton
- Xenon
- Sulfur Hexaflouride
- C-25
- C-8
- C-2
- C-75
- A-75
- A-25
- A-1025
- Star29
- P-5
Custom gas mixes with up to 4 of the listed gases can be created. Please contact Alicat to inquire about gas custom gas mixtures.
Class 1 Div 2 Mass flow meter operating manualClass 1 Div 2 Mass flow controller operating manual
Mass flow meter product specification
- 0.5SCCM to 50SCCM Full Scale
- 50+ SCCM to 20SLPM Full Scale
- 20+ SLPM to 250SLPM Full Scale
- 250+ SLPM to 3000SLPM Full Scale
Mass flow meter mechanical drawings
Mass flow controller product specification
- 0.5SCCM to 50SCCM Full Scale
- 50+ SCCM to 20SLPM Full Scale
- 20+ SLPM to 100SLPM Full Scale P series valve
- 20+ SLPM to 100SLPM Full Scale
- 100+ SLPM to 3000SLPM Full Scale